Med Phys ; 46(4): e79-e93, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30570754

RESUMO

The American Association of Physicists in Medicine (AAPM) has established a comprehensive Code of Ethics for its members. The Code is a formal part of AAPM governance, maintained as Professional Policy 24, and includes both principles of ethical practice and the rules by which a complaint will be adjudicated. The structure and content of the Code have been crafted to also serve the much broader purpose of giving practical ethical guidance to AAPM members for making sound decisions in their professional lives. The Code is structured in four major parts: a Preamble, a set of ten guiding Principles, Guidelines that elucidate the application of the Principles in various practice settings, and the formal Complaint process. Guidelines have been included to address evolving social and cultural norms, such as the use of social media and the broadening scope of considerations important in an evolving workplace. The document presented here is the first major revision of the AAPM Code of Ethics since 2008. This revision was approved by the Board of Directors to become effective 1 January 2019.


Assuntos
Códigos de Ética , Física Médica/ética , Sociedades Científicas/ética , Comitês Consultivos , Física Médica/normas , Humanos , Estados Unidos
2.
Med Phys ; 35(6): 2452-62, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18649478

RESUMO

We describe a focused beam-stop array (BSA) for the measurement of object scatter in imaging systems that utilize x-ray beams in the megavoltage (MV) energy range. The BSA consists of 64 doubly truncated tungsten cone elements of 0.5 cm maximum diameter that are arranged in a regular array on an acrylic slab. The BSA is placed in the accessory tray of a medical linear accelerator at a distance of approximately 50 cm from the focal spot. We derive an expression that allows us to estimate the scatter in an image taken without the array present, given image values in a second image with the array in place. The presence of the array reduces fluence incident on the imaged object. This leads to an object-dependent underestimation bias in the scatter measurements. We apply corrections in order to address this issue. We compare estimates of the flat panel detector response to scatter obtained using the BSA to those derived from Monte Carlo simulations. We find that the two estimates agree to within 10% in terms of RMS error for 30 cm x 30 cm water slabs in the thickness range of 10-30 cm. Larger errors in the scatter estimates are encountered for thinner objects, probably owing to extrafocal radiation sources. However, RMS errors in the estimates of primary images are no more than 5% for water slab thicknesses in the range of 1-30 cm. The BSA scatter estimates are also used to correct cone beam tomographic projections. Maximum deviations of central profiles of uniform water phantoms are reduced from 193 to 19 HU after application of corrections for scatter, beam hardening, and lateral truncation that are based on the BSA-derived scatter estimate. The same corrections remove the typical cupping artifact from both phantom and patient images. The BSA proves to be a useful tool for quantifying and removing image scatter, as well as for validating models of MV imaging systems.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Difração de Raios X , Simulação por Computador , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Radiografia Abdominal , Água/química
3.
Med Phys ; 31(3): 443-62, 2004 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15070241

RESUMO

An electron multileaf collimator (eMLC) has been designed that is unique in that it retracts to 37 cm from the isocenter [63-cm source-to-collimator distance (SCD)] and can be deployed to distances of 20 and 10 cm from the isocenter (80 and 90 cm SCD, respectively). It is expected to be capable of arc therapy at 63 cm SCD; isocentric, fixed-beam therapy at 80 cm SCD; and source-to-surface distance (SSD), fixed-beam therapy at 90 cm SCD. In all positions, its leaves could be used for unmodulated or intensity-modulated therapy. Our goal in the present work is to describe the general characteristics of the eMLC and to demonstrate that its leakage characteristics and dosimetry are adequate for SSD, fixed-beam therapy as an alternative to Cerrobend cutouts with applicators once the prototype's leaves are motorized. Our eMLC data showed interleaf electron leakage at 15 MeV to be less than 0.1% based on a 0.0025 cm manufacturing tolerance, and lateral electron leakage at 5 and 15 MeV to be less than 2%. X-ray leakage through the leaves was 1.6% at 15 MeV. Our data showed that beam penumbra was independent of direction and leaf position. The dosimetric properties of square fields formed by the eMLC were very consistent with those formed by Cerrobend inserts in the 20 x 20 cm2 applicator. Output factors exhibited similar field-size dependence. Airgap factors exhibited almost identical field-size dependence at two SSDs (105 and 110 cm), consistent with the common assumption that airgap factors are applicator independent. Percent depth-dose curves were similar, but showed variations up to 3% in the buildup region. The pencil-beam algorithm (PBA) fit measured data from the eMLC and applicator-cutout systems equally well, and the resulting two-dimensional (2-D) dose distributions, as predicted by the PBA, agreed well at common airgap distance. Simulating patient setups for breast and head and neck treatments showed that almost all fields could be treated using similar SSDs as when using applicators, although head and neck treatments require placing the patient's head on a head-holder treatment table extension. The results of this work confirmed our design goals and support the potential use of the eMLC design in the clinical setting. The eMLC should allow the same treatments as are typically delivered with the electron applicator-cutout system currently used for fixed-beam therapy.


Assuntos
Elétrons , Aceleradores de Partículas , Radiometria/métodos , Radioterapia Conformacional/métodos , Ar , Algoritmos , Imagens de Fantasmas , Espalhamento de Radiação , Raios X